Technical data
Breaking currents: | KB Simplex devices | 30 up to 1200 A in 13 Stages |
| MHB Mini - Statomat | 30 up 100 A, up 40 A incl. Brake Contactor |
| KB Duplex devices | 30 + 30 A up to 200 + 200 A in 16 Stages Also refer selection list for this! |
Setting current range: | 0 - 20 % |
|
| 0 - 50 % | can be programmed |
| 0 - 80 % | using DIP-Switch |
| 0 - 100 % |
|
Safeguarding: | Refer selection list! |
|
Operating voltage: | 400 VAC, 500 VAC, 600 VAC | +10 % / -90 % |
Controlling voltage: | 18 VAC, 24 VAC, 42 VAC, 115/230 VAC | +/- 20 % |
Power consumption of controlling voltage: |
| max. 10 VA |
Admissible storage temperature: |
| -25° C up to +70° C |
Admissible operating temperature/ambience temperature: |
| -10° C up to +45° C |
Temperature rise at maximum breaking current up to 20 Seconds of duration:
|
| max. 30° C; cooling to 10 % wihtin 40 sec. |
Safety class: | IP00 Plastic housing | (Metal housing with safety cable connection ) |
Voltage proof and circuit and control voltage terminals: |
| > 4 KV (not connected) |
Over voltage safety for voltage peaks in micro and milli-seconds range:
|
|
|
400 V: | 3,0 x U N | Additional peak voltage and TSE- |
500 V: | 2,8 x U N | Limitation using integrated varistors and |
600 V | 2,6 x U N | RC-Wiring (Snubber-Link) |
Shake proof: | As per DIN ICE 68 |
|
Function control plate: | Through contacted, with both sided highly isolating photoresist, conventional assembly.
|
|
Time range: | 0...10 sec. | Can be programmed using DIP-Switch |
| 0...15 sec. | Time precision +/- 10 % Precision of |
| 0...20 sec. | repetition +/- 0,5 % |
| 0...30 sec. |
|