The integrated standstill detector requires an additional motor feed line (W likewise N1). This line feeder is to be secured with 200mA/F-Backup. In case of voltage connection the green LED of the detector shows the standstill. It goes off as soon as the motor is started. The detector needs a minimum post braking time for operation. This time is set using the braking time. If the post braking time is set low, then the detector remains at the standstill display. It can be regulated or readjusted by rotating the time potentiometer. The evaluation of the condition of the detector can also take place using the relay outputs 9-10-11 (9-10: NC, 10-11: NO). The braking time consists of the detection time till almost the motor and the post braking time coming into effect after it.  The Post-braking time is to be selected in such a way, that the motor stops securely after the braking.

 