Technical data

Breaking currents:

KB Simplex devices

30 up to 1200 A in 13 Stages

 

MHB Mini - Statomat

30 up 100 A, up 40 A incl. Brake Contactor

 

KB Duplex devices

30 + 30 A up to 200 + 200 A in 16 Stages

Also refer selection list for this!

Setting current range:

0 - 20 %

 

 

0 - 50 %

can be programmed

 

0 - 80 %

using DIP-Switch

 

0 - 100 %

 

Safeguarding:

Refer selection list!

 

Operating voltage:

400 VAC, 500 VAC, 600 VAC

+10 % / -90 %

Controlling voltage:

18 VAC, 24 VAC, 42 VAC, 115/230 VAC

+/- 20 %

Power consumption of controlling voltage:

 

max. 10 VA

Admissible storage temperature:

 

-25° C up to +70° C

Admissible operating temperature/ambience temperature:

 

-10° C up to +45° C

Temperature rise at maximum breaking current up to 20 Seconds of duration:

 

 

max. 30° C; cooling to 10 % wihtin 40 sec.

Safety class:

IP00  Plastic housing

(Metal housing with safety cable connection )

Voltage proof and circuit and control voltage terminals:

 

> 4 KV (not connected)

Over voltage safety for voltage peaks in micro and milli-seconds range:

 

 

 

400 V:

3,0 x U N

Additional peak voltage and TSE-

500 V:

2,8 x U N

Limitation using integrated varistors  and

600 V

2,6 x U N

RC-Wiring (Snubber-Link)

Shake proof:

As per DIN ICE 68

 

Function control plate:

Through contacted, with both sided highly isolating photoresist, conventional assembly.

 

 

Time range:

0...10 sec.

Can be programmed using DIP-Switch

 

0...15 sec.

Time precision +/- 10 % Precision of

 

0...20 sec.

repetition +/- 0,5 %

 

0...30 sec.

 

 

 

 

Seite druckenSeite drucken

Shop
Softstarter
Braking device
MHB - Mini Statomat
AER Statomat simplex
Stand still detector
Measurements AER
Technical Data
Selection list
Bedienungsanleitung
AER duplex device
HBR
Frequency inverter
Electr. Reversal circuit
AC power controller
Module
Downloads
About us
Sitemap
Suche

7. September 2010

 

Deutsch
Türkçe
English
Polski