Technical data

 

 

Items

 

Constants

 

Input

 

Rated Voltage Range

 

3-phase 400V±15%; single-phase 230V±15%

 

Rated Frequency

 

50/60Hz

 

Output

 

Rated Voltage Range

 

3-phase 0400V;3-phase 0230V

 

Frequency Range

 

0.00650.0Hz

 

V/F Control

 

Carrier Frequency

 

3000~10000Hz

 

Input Frequency Resolution

 

Digital setting: 0,01 Hz, analog setting: max. ff frequency x 0,1   %

 

Control Mode

 

VVVF control

 

Overload Capacity

 

150% rated current, 60 seconds.

 

Torque Elevating

 

Manual Torque Promotion 0.1%~30.0% (VVVF)

 

V/F Curve

 

3 kinds of modes: beeline type, and under-defined V/F curve.

 

DC Braking

 

DC braking frequency: 1.0~5.0 Hz, , braking time: 0.0~10.0s

 

Jogging Control

 

Jogging frequency range: min frequency~ max frequency, jogging acceleration/deceleration  time: 0.1~3000.0s

 

Auto Circulating Running and multi-stage speed running

 

Auto circulating running or terminals control can realize 15-stage speed running.

 

Built-in PI adjusting

 

easy to realize a system for process closed-loop control

 

Operation

Function

 

Frequency Setting

 

Potentiometer or external analog signal (05V, 010V, 020mA); keypad (terminal)keys, external control logic and automatic circulation setting.

 

Start/Stop Control

 

Passive contact switch control, keypad control or communication control.

 

Running Command Channels

 

3 kinds of channels from keypad panel, control terminal and series communication port.

 

Frequency Source

 

Frequency sources: given digit, given analog voltage, given analog current and given series communication port.

 

Accessorial frequency Source

 

Flexible implementation of 5  kinds of accessorial frequency fine adjustments and frequency compound.

 

Optional

 

Built-in RFI filter, built-in braking unit, Modbus communication, local operation panel with potentiometer, telecontrol panel

 

Protection Function

 

Input out-phase, Output out-phase, input under-voltage, DC over-voltage, over-current, over-load, current stall, over-heat, external disturbance

 

Display

 

LED nixie tube showing present output frequency, present rotate-speed (rpm), present output current, present output voltage, present linear-velocity, types of faults, and parameters for the system and operation; LED indicators showing the current working status of inverter.

 

Environment

Conditions

 

Equipment Location

 

In an indoor location, Prevent exposure from direct sunlight, Free from dust, tangy caustic gases, flammable gases, steam or the salt-contented, etc.

 

Environment Temperature

 

-10°C ~ 50°C

 

Environment Humidity

 

Below 90% (no water-bead coagulation)

 

Vibration Strength

 

Below 0.5g (acceleration)

 

Height above sea level

 

1000m or below

 

Applicable Motor

 

0.27.5KW

 

 

 

 

Seite druckenSeite drucken

Shop
Softstarter
Braking device
Frequency inverter
E1000
Technical data
Bedienungsanleitung
Electr. Reversal circuit
AC power controller
Module
Downloads
About us
Sitemap
Suche

6. September 2010

 

Deutsch
Türkçe
English
Polski

Details