| Dimensions (W x H x D) in mm |
55 x 75 x 134 |
| Main voltage area |
Standard 400V, ± 10%, 115V-690V on request |
| Controlling voltage area (optional) |
Standard 230V ± 10%, other voltages available on request |
| Power area |
11kW in case of intermediate switching cycles |
| Power consumption of electronics |
2,8VA |
| Safeguarding the main circuit |
The motor should be safeguarded after its connected load. |
| Safeguarding the controlling circuit (optional) |
According to the controlling circuit construction. |
| Supply frequency |
50/60Hz |
| Admissible switching cycle (Standard value) |
ca. 20 Starts/h. Thereby IAN x TAN £ 4 x IN x 10s. With the start up current measured by IAN º, TAN º actual start up time, IN º rated current of the motor. |
| Safety type |
IP00 |
| Installation guidelines |
Only for switch cabinet installation |
| Storage temperature |
-20°C - +80°C |
| Operational temperature |
-20°C - +60°C |
| Relative air humidity |
0% - 90%, non condensing |
| Max. Cross section of connection of clamps and the rating of relay outputs |
2,5qmm, // max. 250VAC / 16A, likewise 30VDC / 16A |